Fuel_Injector_Cleaning_Procedure
PROCEDURE:
1. Relieve the system pressure, refer to FUEL SYSTEM PRESSURE RELIEF.
2. Disconnect the fuel supply line from the inlet of the fuel rail.
3. Attach the fuel supply line to the return line.
4. Plug the fuel return fitting at the fuel rai or connect to tester/cleaner
depending on configuration.
5. Connect the fuel supply hose from the tester/cleaner to the fuel supply
manifold.
6. Turn the tester/cleaner "ON". Tester/cleaner should run 10 minutes.
7. START the engine and check the fuel lines for leakage. If there is any sign
of leakage, turn the vehicle and the tester/cleaner "OFF" and repair
the location where fuel is leaking. Then return to Step 6.
8. When the engine speed has stabilized, set the idle speed at 2000 rpm. Run the
remainder of the
10 minute cycle to eliminate all the air in the fuel supply hose and fuel rail.
9. Turn power switch "OFF" and disconnect power lines.
10. Disconnect cleaner supply hose from the fuel supply manifold.
11. Connect vehicle fuel lines. START engine and check for leaks. Lubricate
O-rings prior to installation and ensure fuel lines are securely connected.